• THEORETICAL FOUNDATIONS AND SPECIFICITY OF MATHEMATICAL MODELLING

    Study of the model for estimating the degree of influence of distortion on image quality with the application of an entropic measure

    Mathematical Modeling, Vol. 5 (2021), Issue 3, pg(s) 83-85

    The article deals with the problem of comparative analysis of the experimental results of using standard-free quality assessment measures depending on the type of distortion applied to the image. The previously developed measure based on the Weibullian model of the gradient magnitude and the entropy measures applied both to the original image and to the gradient characteristics of the ima ge are considered as No-Reference quality measures. Weibull distribution parameters are estimating using a set of image gradient magnitudes using the Sobel operator. A series of experiments was carried out on texture images from the well-known Brodatz texture database and the TID2013 database, which contains images distorted by various types. It was observed that texture images are in good agreement with the Weibullian model, which makes it possible to effectively apply the above-mentioned No-Reference measures and carry out a comparative analysis. The use of the TID2013 database with 3000 images, distorted by 24 types, each at five levels, makes it possible to evaluate additionally the effectiveness of the entropy approach to assessing image quality, comparing them with visual assessments also given in the database. Then it was illustrated that applying the entropy approach directly to the original image gives a worse result than applying image gradients to the magnitude. At the same time, a higher sensitivity to structural changes from the level and type of applied distortions is observed. The problem of the expediency of calculating the entropy using estimates of the parameters of the Weibull distribut ion instead of the histogram of the array of gradient magnitudes is investigated separately. The paper contains numerical and graphical materials illustrating the obtained results.

  • NEW METHODS FOR MEASURING THE PROPERTIES OF ANTIBIOGENIC COATINGS OF MEDICAL TITANIUM IMPLANTS FOR TRAUMATOLOGY AND ORTHOPEDICS

    Machines. Technologies. Materials., Vol. 12 (2018), Issue 8, pg(s) 333-337

    The work is a part of researches of the technical characteristics of 20 types of medical titanium implants for traumatology and orthopedics with antibiogenic coating of titanium and hafnium nitrides in accordance with technical conditions of the manufacturer of the implants – JSC “Medmash”, Russia. Based on a titanium alloy the implant with antibiogenic coating is a product coated with titanium and hafnium nitride by high-frequency magnetron sputtering.
    In the present article, the structure, phase composition, distribution of elements on the surface and thickness (Ti-Hf)N-coatings with different hafnium content (Ti:Hf ratio) were investigated. The studies were carried out on model samples in the form of plates of titanium alloy VT6, which were coated with titanium and hafnium nitride by magnetron sputtering. Also, changes in the thickness of the hardness and modulus of elasticity of the coatings were measured by the method of instrumental indentation. The maximum values of hardness (~35 GPa) and modulus of elasticity (~500 GPa) were obtained from coatings of composition (Ti0.85Hf0.15)N and (Ti0.8Hf0.2)N. The coatings with these compositions have the most uniform Hf thickness distribution.