STRUCTURE AND CHARACTERISTICS COMPLEX DIFFUSION LAYERS AFTER SATURATION BORON AND COPPER ON STEEL
Machines. Technologies. Materials., Vol. 8 (2014), Issue 10, pg(s) 39-42
Investigated the wear resistance of coatings obtained by saturation with boron and copper under dry friction – sliding on the air, and found that the coatings obtained by saturation with boron and copper have 2 times better wear resistance than the coating after boriding. Found that the saturation of boron and copper complex provides optimal performance when wear boride phases, namely sufficient microhardness – 15.5 MPa, 0,5 0,5 low porosity, increase in viscosity layer, the value K reaches 2.1 MPa · m to compared with 1.2 MPa · m 1C without complex saturation and increasing stress chipping values to 290 MPa compared to 170 MPa for the boride layers.